Description: Beacon 200/ two channel controller/ 115-220 VAC (no sensor) Features Simultaneous readout on 2 channels Two alarm levels per channel Discrete and common relays NEMA 4X enclosure 4-20 mA outputs Proven, long-life sensors for a wide variety of g

$2,278.42 $148.00

Share :

Description: Beacon 200/ two channel controller/ 115-220 VAC (no sensor)

Features

  • Simultaneous readout on 2 channels
  • Two alarm levels per channel
  • Discrete and common relays
  • NEMA 4X enclosure
  • 4-20 mA outputs
  • Proven, long-life sensors for a wide variety of gases
  • Accepts any 4-20 mA transmitter input (24 VDC)
  • Easy to install, operate and expand

Description

The Beacon 200 is a powerful, low cost fixed system controller for two points of gas detection. It is microprocessor controlled, versatile, simple to install and operate, and priced to be the industrys most economical two point controller. It is capable of connecting directly to RKI sensors for LEL level combustibles, Oxygen, Hydrogen Sulfide, or Carbon Monoxide. The Beacon 200 can also accept any 4-20 mA transmitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the Beacon 200 housing, or can be wired remotely from the controller.

The 10 amp rated relays are strong enough to actuate most external alarms and horns without using slave relays. The digital display has backlighting and simultaneous readout of the gas type and concentration.

The Beacon 200s housing is rated NEMA 4X for corrosion resistance and a weather tight seal, and complies with lock out / tag out standards. An external reset switch allows the alarm to be silenced from outside of the controller housing. The Beacon 200 comes complete with a wall mounting kit for easy installation.

RKI offers the industrys widest selection of standard and toxic gas detection sensors, which can be utilized with the Beacon 200, providing gas monitoring protection for almost any application.

Specifications

Physical

Dimensions Height: 10.5 267 mm Width: 8.5 216 mm Depth: 6.3 158 mm Enclosure Wall mounting grey polycarbonate with hinged cover Conduit Connection 3/4 NPT conduit hubs, 3 provided. 2 for sensor wiring and 1 for power & relay wiring Wiring Termination Screw type terminal block, 14 gauge max Controls 4 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset

Environmental

Operating Temp -4F to 122F (-10C to 50C) Storage Temp -4F to 158F (-20C to 70C) Relative Humidity 0 100% RH Enclosure Rating NEMA-4X enclosure, waterproof, chemical, and weather resistant

Inputs

Direct Wired Sensors LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide Remote amp not required for less than 500 feet 4-20 mA Sensors Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet Sampling Methods Diffusion and sample draw heads available

Outputs

Relays 7 relays 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarm levels per channel, plus 2 relays for common gas alarm and 1 common relay for malfunction. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off 4-20 mA Signal output, 4-20 mA (into 1000 ohms impedance maximum), per channel 24 VDC 24 VDC (350 mA max) output provided to operate sample drawing adapters or other accessories Display Alphanumeric display with backlighting. 20 characters per line; 4 lines each Audible Built-in audible alarm, 94 dB, mounted on enclosure Coded output: pulsing = gas alarm, steady = fail Visual 4 LEDs on the front cover for alarm status indication, pilot, and malfunction Optional Expansion Cards Individual 4-20 mA (or 1 5 VDC) outputs Heavy duty relay card (4 each @ 30 amps)

Power

110-240 VAC or 24 VDC standard. Battery backup option available

Warranty

One year materials and workmanship Partial List Of Detectable Gases Many other gases or ranges available. Contact RKI for gases or ranges not listed. Ammonia (NH3) 0 75.0 ppm Arsine (AsH3 ) 0 0.20 ppm Boron Trichloride (BCl3) 0 15.0 ppm Carbon Dioxide (CO2) 0 1.0 % Carbon Monoxide (CO) 0 300 ppm Chlorine (Cl2) 0 3.0 ppm Chlorine Dioxide (ClO2) 0 1.00 ppm Chlorine Trifluoride (ClF3) 0 1.00 ppm Combustibles 0 -100% LEL Diborane (B2H6) 0 30.0 ppm Fluorine (F2) 0 6.0 ppm Hydrogen (H2) 0 2000 ppm Hydrogen Chloride (HCl) 0 15.0 ppm Hydrogen Fluoride (HF) 0 9.0 ppm Hydrogen Sulfide (H2S) 0 -100.0 ppm Nitric Oxide (NO) 0 -100.0 ppm Nitrogen Dioxide (NO2) 0 15.0 ppm Nitrogen Trifluoride (NF3) 0 30.0 ppm Oxygen (O2) 0 25.0 % Ozone (O3) 0 1.0 ppm Phosphine (PH3) 0 1.0 ppm Silane (SiH4) 0 15.0 ppm Sulfur Dioxide (SO2) 0 30.0 ppm TEOS (Si(OC2H5)4) 0 -15/30 ppm

Specifications subject to change without notice. Made in the USA